LIMIT SWITCHES > Top Entrance Rope Operated
Previous Page | Next Page | View Printer-Friendly Page

General Specifications

Enclosure: Die cast metal with baked epoxy powder coating.
Conduit Entry: One PG13.5 Entry (PG13.5 to ½ NPT conduit adapter furnished standard)
Mechanical Endurance:
    Life Cycle: 1 Million Operations
    Operating Temperature Range: -13° + 175° F (-25° + 80° C)
    Activating Speed Minimum: 0.039 inches / sec (1 mm / sec)
Standards:
    UL 508, CSA C22-2nr.14, CEI EN 60947-5-1, EN 292, EN 418, EN 1088, EN 60204, EN 60947-5-1,
    IEC 204, IEC 337-1, IEC 947-5-1, NFC 63-140, VDE0113, VDE 0660, BG-GS-ET-15
Positive Break Contacts standards: CEI EN60947-5-1, EN 60947-5-1, IEC 947-5-1, VDE0660-206
Protection Class: IP66 (according to IEC529)
Operating Force:
    Initial: 14 lbs. (64 N)
    Final: 19 lbs. (83 N)
Recommended Maximum Operating Distance
    Without intermediate supports: 19.5 feet (6 meters)
    With intermediate supports: 39.4 feet (12 meters) - Intermediate support every 9.8 feet (3 meters)

Installation

  1. Connect the circuits to the Normally Closed contact or the Normally Open contact as needed. The contacts can be wired in series. When the rope is properly tensioned and the operating ring is extended as shown in Figure 1, both contacts are "Closed". If the rope is released, the normally open contact opens. If the rope is pulled, the normally closed contact opens. Either action transfers the contacts.
  2. Mount the switch using washers under the switch mounting fasteners (not supplied) to prevent the fasteners from pulling through the switch mounting holes.
  3. The head of the switch can be rotated in 4 x 90 degree steps allowing 4 different rope pull positions. To rotate the head remove the 4 head attachment screws, rotate the head into the proper position and reinsert the head attachment screws.
    Head Screw Tightening Torque = 7 inch lb. (0.8 Nm)
  4. Rope tensioning (see Figure 1):
    The rope is properly tensioned when the activating rod is extended approximately
    5/32" (4 mm) - see Figure 1. Once the activating rod is positioned the Automatic version automatically closes the Normally Open contact. To close the Normally Open contact in the Manual version, pull out the "Reset" knob.
  5. The contacts open if the tensioned activating rope is either cut or pulled. To reset the switch reset the rope tension as described in Item 4.
  6. Do not use the switch as a mechanical stop.
  7. Verify proper operation of the Rope Pull Switch before placing the machine in service.

Figure 1

Typical Rope Installation

Click for Larger Image in a New Window

 